NVS Parameter: aldly pud


Long Name:

picker_up_down

Applies to:

  • Trendsetter_400/800_Auto
  • Trendsetter_NEWS

  • Description:

    This value specifies the maximum time to wait when moving the picker up or down. If the picker up/down sensors are enabled, the system will wait until either the sensors are activated or this amount of time has expired. If the sensors are enabled and the time has expired, the system will suspend with an error message. If the sensors are disabled, the system will wait for the full amount of time specified by this parameter.

    For the version 3 picker, the DOWN sensor goes high before the picker is fully down. The system will wait an additional 1.5s (hard-coded) before declaring the picker in the DOWN state.


    Type:

    uint32

    Default:

    • 10

    Range:

    • 0 to 60 [seconds]

    Notes:


    Partition:

    cal

    See Also:

  • NVS: al puds
  • NVS: al vpi

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:18 2002 PST