NVS Parameter: aldly shut


Long Name:

shutter_delay

Applies to:

  • Trendsetter_400/800

  • Description:

    For platesetters, shutter_delay specifies the cassette top-shutter timeout. For Trendsetters, shutter_delay specifies the amount of delay before the exit door is closed when unloading a plate with "load plate sensor" disables.


    Type:

    integer

    Default:

    • 4000

    Range:

    • 0 to 60000 [seconds]

    Notes:

    Please note that for Trendsetters, this parameter has no effect IF the load plate sensor is enabled.


    Partition:

    cal

    See Also:

  • NVS: al lps

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page