Long Name: | side_shift_on_exit |
Applies to: |
|
Description: |
This value specifies the amount of side-to-side shift of the plate after rotation. Setting this parameter to a positive value will shift the plate to the left after rotation (when viewed from the front of the Trendsetter). Setting this value negative will shift the plate to the right. |
Type: | int32 |
Default: |
|
Range: |
|
Notes: |
It is possible to shift very large plates so far that they will hit the back of the machine during rotation. Do not decrease the alpos ssoe parameter past about -50mm for 44" plates. This parameter is only present in firmware versions after and including V1.30. |
Partition: | cal |
See Also: |
|
Go to CTP Firmware NVS Parameter Index Page