NVS Parameter: alpos ssoe


Long Name:

side_shift_on_exit

Applies to:

  • Trendsetter_400/800_Auto

  • Description:

    This value specifies the amount of side-to-side shift of the plate after rotation.

    Setting this parameter to a positive value will shift the plate to the left after rotation (when viewed from the front of the Trendsetter). Setting this value negative will shift the plate to the right.


    Type:

    int32

    Default:

    • 0

    Range:

    • -100 to 100 [mm]

    Notes:

    It is possible to shift very large plates so far that they will hit the back of the machine during rotation. Do not decrease the alpos ssoe parameter past about -50mm for 44" plates.

    This parameter is only present in firmware versions after and including V1.30.


    Partition:

    cal

    See Also:

  • NVS: al ri
  • NVS: bay rp

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:23 2002 PST