NVS Parameter: state bay rp


Long Name:

rotate_plate

Applies to:

  • Trendsetter_400/800_Auto

  • Description:

    The rotate_plate parameter is used to selectively enable the plate rotator.

    This state parameter is not normally modified with the 'set' command. The firmware uses this parameter for internal 'housekeeping'.

    Print Console V2.0 or higher:

    This parameter will be updated as part of the load bay command. It should NOT be set manually.

    If this parameter is set to 0, then the plate will NOT be rotated before being fed into the processor.

    If this parameter is set to 1, then the plate WILL be rotated 90 degrees before being fed into the processor.

    Allegro workstation software:

    This parameter must be set through diagnostics, and that setting will be used on all plates.

    If this parameter is set to 0, then the plate will NOT be rotated before being fed into the processor.

    As of firmware V1.40:

    If this parameter is set to 1, then the firmware will always present the shortest edge to the processor. Plates loaded in portrait will not be rotated; plates loaded in landscape will be rotated 90 degrees prior to being fed into the processor.

    If this parameter is set to 2, then ALL plates will be rotated 90 degrees prior to being fed into the processor.

    Prior to firmware V1.40:

    If this parameter is set to 1, then the plate WILL be rotated 90 degrees before being fed into the processor.


    Type:

    uint8

    Default:

    • 1

    Range:

    • 0 to 2

    Notes:

    This parameter will automatically be copied into "state plate_loc" when a plate is picked.


    Partition:

    state

    See Also:

  • NVS: al ri
  • NVS: plate_loc rp

  • Go to CTP Firmware NVS Parameter Index Page