NVS Parameter: alproof si


Long Name:

sensors_installed

Applies to:

  • Trendsetter_400/800_Proofing

  • Description:

    Enables or disables all the actuator, door, and cassette sensors on the proofing loader and front door. This parameter does not affect the vacuum sensors.

    Set to 0 to bypass the sensors.

    Set to 1 to enable the sensors.


    Type:

    byte

    Default:

    • 1

    Range:

    • 0 to 1 (no units)

    Notes:

    When bypassed, the time required to load or unload a piece of media will increase substantially (up to 50%). This is because the machine needs to wait the worst-case time for an actuator to travel it's distance, instead of simply waiting for the sensor.


    Partition:

    cfg

    See Also: