NVS Parameter: carriage espot


Long Name:

edge_spot_width

Applies to:

  • Green

  • Description:

    The number of pixels turned on during an edge search. Should not be changed from the default. An incorrect number of pixels can significantly affect edge detection accuracy.

    Service note: If you need to change the number of pixels used to find the edge, either the amount of light coming out of the head is set very wrong or the amount of light reflecting back to the head is very wrong. In the first case hdp epwr needs to be adjusted, and in the second case drum epos needs to be adjusted. The HRX edge detect setup script will set both epos and epwr. It is available on the hrx support pages (url listed below).


    Type:

    integer

    Default:

    • 3

    Range:

    • 0 to 10 [pixels]

    Notes:


    Partition:

    cfg

    See Also:

  • NVS: hdp epwr
  • NVS: drum epos
  • Other: HRX edge detect script

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:30 2002 PST