NVS Parameter: carriage msspeed


Long Name:

max_skip_speed

Applies to:

  • All

  • Description:

    This sets the maximum allowable carriage speed while skipping, in mils per second. The acceleration towards skip velocity is linear as opposed to the acceleration towards move velocity which is optimized as a curve. Therefore, this velocity should be set about 20 percent below the maximum carriage speed ("carriage mspeed") to ensure the carriage doesn't stall while accelerating to skip velocity.

    The actual carriage skip velocity will be an integer ratio of the plot velocity. This is necessary so the swath boundaries remain in the same position when plotting resumes. Given the maximum skip speed and the other skipping-related parameters, the carriage firmware will calculate the highest possible ratio for the skipping velocity (referred to as the "blank skip ratio").


    Type:

    uint16

    Default:

    • 2000

    Range:

    • 100 to 5000 [mil/sec]

    Notes:

    Only present on machines equipped with the blank skipping feature. Only used by the firmware at the start of a plot when blank skipping is enabled (see "carriage skip").


    Partition:

    cfg

    See Also:

  • NVS: carriage mspeed
  • NVS: carriage skip
  • NVS: carriage mswidth

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:30 2002 PST