NVS Parameter: carriage wsearch


Long Name:

edge_wide_search

Applies to:

  • All

  • Description:

    Edge search distance on second pass (twice this distance on the third pass, etc). The search is centred on the expected plate edge position, i.e. started half the search distance from the expected plate edge. If this is the first plate from a bay after it has been loaded, this search distance is used on the first pass. Normally not changed from default. If the autoloader is having problems placing plates from the same bay in the same spot each time, this parameter could be increased slighlty to optimize edge search time. Otherwise, if this parameter is too small, the "edge not found" error may be reported or the first pass after bay loading may fail too often. If this parameter is too large, this pass may take longer than necessary. Both cases will result in increased average search times for the first plate out of a bay.


    Type:

    integer

    Default:

    • 1000

    Range:

    • 0 to 10000 [mils]

    Notes:


    Partition:

    cfg

    See Also:

  • NVS: carriage wsearch
  • NVS: carriage eatt

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:31 2002 PST