NVS Parameter: config ssz


Long Name:

sscan_size

Applies to:

  • All

  • Description:

    The operator will not be able to image a plate that is larger than the sscan_size that is specifed in the dongle.

    The dongle is a security device that is connected to a serial port on the back of the MPE backplane. The dongle is programmed during integration and cannot be changed in the field. The dongle's contents are read by the MPE firmware when the machine is running.

    Instead of a dongle, the 3230/3244 Base Trendsetter 'b' (starting at V2.31) and the 3230/3244 Trendsetter Autoloader (starting at V1.30) use the "config" command to specify a machine type. That command automatically configures several NVS parameters, including the "config ssz" parameter.


    Type:

    integer

    Default:

    • 44 (Platesetter_3244, Trendsetter_400/800)
    • 80 (Platesetter_VLF, Trendsetter_VLF)
    • 37 (Trendsetter NEWS)

    Range:

    • 0 to 254 [inches]

    Notes:

    Currently, only the VLF Platesetter uses the dongle. There are no plans to support the dongle on the Green 3244 Platesetters in the future.


    Partition:

    cfg

    See Also:

  • Command: config
  • NVS: config type

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:31 2002 PST