NVS Parameter: drum dgr


Long Name:

deriv_gain_run

Applies to:

  • Platesetter_VLF
  • Trendsetter_VLF
  • ThermoFlex

  • Description:

    The derivative gain for the drum servo once the drum reaches the desired velocity in the constant velocity mode. While accelerating the dgv value is used.


    Type:

    integer

    Default:

    • 0

    Range:

    • 0 to 65534

    Notes:

    Separate from velocity mode parameters to allow servo to be tuned for optimal smoothness while plotting.


    Partition:

    cal

    See Also:

  • NVS: drum dgv

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:32 2002 PST