NVS Parameter: hdp lrt


Long Name:

laser_ready_time

Applies to:

  • Thermal

  • Description:

    Workstation images cannot be launched until this timer expires. The timer starts when the door is closed or after the thermal head has completed initializing.

    When a door is opened, the 24V/48V to the head is lost. This effectively disables the laser beam positioning. When the door is closed, the 24V/48V to the head is reenabled. A certain time must pass before the laser is turned on to allow the beam positioning to stabilize.

    Note that the "laser on" command can be used before the timer expires. It may or may not be successful. An appropriate error message is generated if the command is not successful.


    Type:

    integer

    Default:

    • 180

    Range:

    • 0 to 1800 [seconds]

    Notes:


    Partition:

    cfg

    See Also:

  • Error: E_HEAD_BP_OK_TIMEOUT

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page