Error Number: 17724


Error Message:

HEAD: Laser beam positioning not stable yet


Applies to:

  • Thermal

Service Information:

An attempt to turn on the laser beam (ie with "laser on") before the beam positioning has stablized will cause this error. In this case simply try again. It may be necessary to initially start the laser with "laser on", "head bp on" initially if the stored thermal rod hold current is way off for some reason.

If problem persists and you have thermal head version greater than 1.56 it is easily possible to diagnose the exact problem by using the internal data collection capabilities (see release notes or head diag0 information). Also with 1.56 the command "laser test" may diagnose the problem.


Operator Action:

Cancel current job and try again. If the problem persists, call service immediately.


Cause:

  • Beam pointing is too far off to start the laser within the laser on timeout. In this case trying again will likely fix the problem. If the beam positioning servo is not working properly, the laser will never be able to be turned on successfully.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page