NVS Parameter: head scanscale


Long Name:

scan_corr_scale

Applies to:

  • Thermal

  • Description:

    Used only in conjunction with the plate scan automatic banding correction. Set as a result of the "plot phase" command. There should never be any need to adjust this parameter manually and the setting will not affect imaging.

    Sets the scale factor to convert a measured density difference into a scorr table percentage.


    Type:

    integer

    Default:

    • 0

    Range:

    • -1000 to 1000

    Notes:


    Partition:

    cal

    See Also:

  • NVS: head scanscale
  • Command: plot phase
  • Command: plot flatten

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:39 2002 PST