NVS Parameter: laser tinit


Long Name:

laser_warmup_time

Applies to:

  • Green

  • Description:

    Ignored when "laser ver" set to 0 (no laser). If laser ver = 1 or 2 (Adlas laser or adlas laser integration mode), the default value of tinit is 10. It may be set as high as 20.

    If laser ver = 10 (Coherent laser), set tinit to 2. There is no feedback from the coherent laser to tell the firmware when the coherent laser is ready. Setting a 2 minute timeout gives the laser time to stabilize before the workstation is permitted to launch jobs.


    Type:

    integer

    Default:

    • 10

    Range:

    • 0 to 254 [minutes]

    Notes:


    Partition:

    cfg

    See Also:

  • NVS: laser ver
  • NVS: laser tcon

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:44 2002 PST