NVS Parameter: media mu


Long Name:

manual_unload

Applies to:

  • Trendsetter_400/800_Auto

  • Description:

    This parameter specifies whether the media should be automatically unloaded and processed, or should be unloaded to the front of the machine and manually removed.

    The objective of this parameter is to allow the Trendsetter Autoloader to image media that can not be put through the on-line processor, and must be manually carried to an alternate processor (as is the case with the semi-automatic Trendsetter).

    If the manual_unload parameter is set to 0, the plate will be automatically unloaded onto the unload table and will be fed into the attached plate processor.

    If the manual_unload parameter is set to 1, the plate will be unloaded back onto the load table and must be manually removed before the next plate can be picked and loaded.


    Type:

    byte

    Default:

    • 0 (Automatic Unload)

    Range:

    • 0 to 1

    Notes:

    This parameter is automatically set to 0 and cannot be changed on E-type machines.


    Partition:

    cal

    See Also:

  • NVS: config type
  • Command: config

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:45 2002 PST