Description:
|
For integrating media such as the T96-3 plate, special care must be taken to avoid image
artifacts. Stray light from the light valve will expose the plate in a very short amount
of time. Specifically, two changes have been made:
- if the job is cancelled any time after the focus learn starts, the plate is considered a
reject. This is because a second focus learn will cause a dark line to appear on the plate.
The error message 16072: “Plate rejected because it was cancelled too late in the imaging
sequence” will indicate this condition.
- retraces cause image artifacts, so are not allowed. Currently, imaging will be completed,
then the machine will suspend with a warning message indicating that retraces occurred. This
lets the operator know that the plate is probably not usable.
For such a media, the new parameter media slf (stray_light_fogging) should be set to 1 to put
into place these extra checks.
|