NVS Parameter: mode sl


Long Name:

series_length

Applies to:

  • All

  • Description:

    Total number of strips, or steps, to image when performing an exposure series. The length of each strip is set with the mode sw parameter. Note that the series may finish before all steps have been imaged if the final exposure levels are not attainable.


    Type:

    integer

    Default:

    • 15

    Range:

    • 1 to 40 [steps]

    Notes:


    Partition:

    cal

    See Also:

  • NVS: mode sw

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page