NVS Parameter: mode sw


Long Name:

series_strip_width

Applies to:

  • All

  • Description:

    The length of each strip when performing an exposure series. The strip width should be chosen to match the repeat period of the test pattern. The default width is chosen to match test pattern 3. Note that "continuous" patterns like the percent screens (30, 50, 80, etc) will work well with any strip width because they do not have a repeat period.


    Type:

    real

    Default:

    • 1.5

    Range:

    • 0.010 to 20.0 [inches]

    Notes:


    Partition:

    cal

    See Also:

  • NVS: mode sl

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:47 2002 PST