NVS Parameter: sys dbhs


Long Name:

dblower_high_stop

Applies to:

  • Trendsetter_VLF
  • Trendsetter_VLF_Auto
  • Trendsetter_400/800
  • Trendsetter_400/800_Proofing
  • Trendsetter_400/800_Auto

  • Description:

    When the debris cabinet is running, the pressure at the nozzle by the head is measured. If the pressure goes above the value indicated by this parameter, the inlet of the debris nozzle is probably blocked, so warning messages are displayed, and the device will suspend at the end of each plot.


    Type:

    integer

    Default:

    • 30

    Range:

    • 0 to 200

    Notes:


    Partition:

    cfg

    See Also:

  • Command: dr
  • NVS: sys dbin
  • NVS: sys dblw
  • NVS: sys dbls
  • NVS: media abl
  • Error: E_DBLOWER_SYSTEM_BLOCKED

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:57 2002 PST