NVS Parameter: sys dblw


Long Name:

dblower_low_warning

Applies to:

  • Trendsetter_VLF
  • Trendsetter_VLF_Auto
  • Trendsetter_400/800
  • Trendsetter_400/800_Proofing
  • Trendsetter_400/800_Auto

  • Description:

    When the debris cabinet is running, the pressure at the nozzle by the head is measured. If the pressure goes below the value indicated by this parameter, the filter of the debris cabinet is probably starting to get full, so warning messages are displayed to the operator.


    Type:

    integer

    Default:

    • 12

    Range:

    • 0 to 200

    Notes:


    Partition:

    cfg

    See Also:

  • Command: dr
  • NVS: sys dbin
  • NVS: sys dbls
  • NVS: sys dbhs
  • NVS: media abl
  • Error: E_DBLOWER_ALMOST_FULL

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:57 2002 PST