NVS Parameter: sys ism


Long Name:

image_size_margin

Applies to:

  • All

  • Description:

    Extends the allowable image size in the carriage travel direction beyond the size of the plate. Normally, this parameter is not changed from the default value. If the "Image too wide for plate" error is reported, it may be due to a slight mismatch in the imposed plate size and the plate size entered in the recorder's bay. Setting this parameter to a few tenths of an inch may solve the problem.

    Starting with version 2.00, it should no longer be necessary to make this parameter non-zero to prevent images from hanging at the end.


    Type:

    integer

    Default:

    • 0

    Range:

    • 0 to 254 ["/10]

    Notes:


    Partition:

    cfg

    See Also:

  • NVS: sys ism

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page