NVS Parameter: sys scanntu


Long Name:

scan_nco_tach_update

Applies to:

  • Thermal

  • Description:

    This parameter is used in the thermal plate scan method of balancing the beam.

    A higher speed may be used to get the PLL to lock thereby sacrificing some signal to noise (ie. a lower drum speed is preferred). As a last resort if PLL lock is not obtained at slow drum speeds then the system nvs parameter scanntu can be set to try it with different ntu values. If this parameter is zero then the scanning routines automatically pick an ntu value derived from the regular ntu value and scaled for the scanning drum speed.

    It is expected that this will almost always work and hence there will be no need to adjust the `scanntu' value but it is there just in case.


    Type:

    integer

    Default:

    • 0

    Range:

    • 0 to 254

    Notes:


    Partition:

    cfg

    See Also:

  • Command: plot flatten
  • Command: plot phase
  • NVS: sys ntu

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:58 2002 PST