| index
| Selects the trigger index from 0 to 4.
|
|
| delay
| Selects the trigger delay from 1 to 65535.
|
Display / configures the trigger event for the acquisition of sample data by the data logger subsystem. The possible trigger events are as follows:
|
|
|
- Automatic (0)
- Laser On (1)
- Focus On (2)
- Newline (3)
- Image (4)
|
|
| The monitor command log trigger will display the trigger events, the monitor command log trigger <index> will configure the trigger event with the default trigger delay and the monitor command log <index> <delay> will configure the trigger event with the specified trigger delay.
|
|
| Note that an automatic trigger event will immediately enable the acquisition of sample data by the data logger subsystem. All other trigger events will wait indefinitely for the trigger event before enabling the acquisition of sample data.
|
Thermal 1.0 / 1.7x equivalents:
|
|
|
- The monitor command log trigger [<index>] [<delay>] does not have an equivalent.
|
COMMAND: log mode (plot|sample|off)
|