Tfx Command
(requires ENG access)
vpc power <media> [<power_points>]

Variables media Media index, numbered from 0.
power_points Up to 7 power_points, used in velocity curve. (mw)

Description The velocity power curve is used with the sleeve engine. When using different sleeve diameters, the surface velocity varies, and the diode power must vary as well to keep exposure constant. The velocity power curves store information on the power required at various surface velocities for each media.

If no power points are specified, the power points for the specified media will be displayed at the monitor.

When power points are specified, this command sets the power points for the velocity power curve for the specified media. There must be one power point for each velocity point on the curve.

Notes These values are set in production, and should not be changed unless you fully understand the consequences. The power points are specified in units of mw.

Related Documents COMMAND: vpc velocity <media> [<velocity_points>]
ERRORCODE: [05300] Invalid function parameter
ERRORCODE: [05307] The specified media index is out of range
PARAMETER: vpc <media> power_points

Applies to: TFX
Access: ENG
Modified: Thu Oct 10 11:47:50 2002
Updated: Thu Jul 17 02:31:31 2008
Module: VPC