Tfx Errorcode
[03210] Both directory sections are corrupt

Service Information The registry consists of three 32K blocks of flash used as primary, secondary and baseline parameter sections. The primary and secondary sections provide a redundant backup for reading and writing registry keys ( or parameters ) while the baseline section provides a baseline for the registry keys ( or parameters ).

The status of the primary and secondary parameter sections is determined automatically during initialization and by the monitor command reg verify. If an error is detected in both the primary and secondary parameter sections, the firmware cannot attempt automatic recovery. User intervention is required to manually recover the registry.

Operator Action Call service.

Causes
  • Corruption in both the primary and secondary parameter sections due to a flash problem.
  • Number of flash write cycles exceeded.

Related Documents COMMAND: reg verify [baseline]
ERRORCODE: [03211] The primary directory section was recovered
ERRORCODE: [03212] The primary directory section is corrupt
ERRORCODE: [03213] The secondary directory section was recovered
ERRORCODE: [03214] The secondary directory section is corrupt

Applies to: TFX THERMAL2 FB1
Modified: Wed Aug 29 16:13:54 2007
Updated: Thu Jul 17 02:31:29 2008
Module: REG