Tfx Parameter
(requires ENG access)
log divisor <index>

Variables index Selects the sample index from 0 to 63.

Description The data logger subsystem will acquire sample data for further analysis. This NVS parameter configures the divisor for the sample points that will be stored during the acquisition of sample data.

While this parameter can be used to configure the divisor for the sample points, it is recommended that the monitor command log sample [<point> (enable|disable)] [<divisor>] be used to configure the divisor for the sample points. The parameters are implemented for permanent storage only.

Type Integer

Default Value 1

Range 1 to 65535

Related Documents COMMAND: log sample [<point> (enable|disable)] [<divisor>]

Applies to: TFX THERMAL2
Access: ENG
Modified: Tue Oct 24 11:40:30 2006
Updated: Thu Jul 17 02:31:32 2008
Module: LOG