Configure the edge detect control mode.
|
|
| The monitor command sys edge standard initiates the "Standard" edge detect control mode. A standard edge detect will detect an edge transition from off-plate to on-plate. The edge detect state is initialized including the logic to generate the interrupt for the host.
|
|
| The monitor command sys edge featureless initiates the "Featureless" edge detect control mode. A featureless edge detect will detect an edge transition from on-plate to off-plate. The edge detect state is initialized including the logic to generate the interrupt for the host.
|
|
| The monitor command sys edge off executes the "Off" edge detect control mode. This will disable the logic to generate the interrupt for the host.
|
|
| The monitor command sys edge will display the edge detect information. The edge detect information is displayed as follows:
|
|
| SYS: Over Media=<Over Media>
|
|
| SYS: Number Of Edges=<Number of Edges>
|
|
| SYS: Delta Time=<Delta Time> us
|
|
| The over media flag will be one of the following:
|
|
|
|
|
| The number of edges indicates the number of valid edge transitions that have been detected by the exposure head. The "Standard" edge detect control mode will detect off-plate to on-plate edge transitions and the "Featureless" edge detect control mode will detect on-plate to off-plate edge transitions.
|
|
| The delta time indicates the difference between the edge detect interrupt and the edge detect position.
|
Thermal 1.0 / 1.7x equivalents:
|
|
|
- The monitor command sys edge (standard|off) is equivalent to head edge (on|off).
- The monitor command sys edge featureless does not have an equivalent.
- The monitor command sys edge is comparable to head sample edge.
|
COMMAND: sys edge reset
|
|
|
PARAMETER: sys plotenable
|
The monitor command sys edge [standard|featureless|off] corresponds to the API functions CEH_EdgeMode( ) and CEH_EdgeInfo( ) in the CEH API document.
|