Configure the system parameters.
|
|
| System parameters are the parameters in the exposure head that the host can read and / or write. The host must write system parameters to the exposure head as required by the exposure head. The host can read system parameters from the exposure head as required by the host.
|
|
| When the host writes a system parameter, the exposure head will write the system parameter but will not configure the system parameter. Since the exposure head will typically require several system parameters, the host will "trigger" the configuration of the system parameters after writing all system parameters required by the exposure head.
|
|
| The monitor command sys parm config will "trigger" the configuration of the system parameters. Note that the monitor command sys parm <index> <value> automatically "triggers" the configuration of the system parameters.
|
Thermal 1.0 / 1.7x equivalents:
|
|
|
- The monitor command sys parm config does not have an equivalent.
|
COMMAND: sys parm access <index> (disable|enable)
|
|
|
COMMAND: sys parm [<index> <value>]
|
The monitor command sys parm config corresponds to the API function CEH_ParameterConfig( ) in the CEH API document.
|