| offset
| Specifies the first spot to configure from 0 to 463.
|
|
| width
| Specifies the number of spots to configure from 1 to 464.
|
Calculate the pulse height for the pixel(s) at all pixel levels. The internal balance calculates the required stroke profile by adjusting the pixel levels. The monitor command ibs level <offset> [<width>] [nocal] can be used to determine the relationship between pixel levels and pulse heights ( it's not linear ). The performance of the internal balance can be improved by determining and compensating for the relationship between pixel levels and pulse heights.
|
|
| For the first version of the internal beam-balance sensor board, the automatic internal beam-balance sensor configuration sets the pixel pair in the center of the stroke to provide a pixel power of 1000 counts at the configured pixel level. If required ( for development purposes only ), the automatic internal beam-balance sensor configuration can be disabled by the optional token nocal. For all other versions of the internal beam-balance sensor board, configuration of the internal beam-balance sensor gain and offset is not required.
|
|
| Note that the level profile will not configure the laser diode driver, beam-pointing driver or light valve driver.
|
Thermal 1.0 / 1.7x equivalents:
|
|
|
- The monitor command ibs level <offset> [<width>] [nocal] does not have an equivalent.
|
|
| Thermal 2 equivalents:
|
|
|
- The monitor command ibs level <offset> [<width>] [nocal] does not have an equivalent.
|
COMMAND: ibs sensor <gain> <offset>
|
|
|
ERRORCODE: [07605] The mode / state of the laser diode is invalid
|
|
|
ERRORCODE: [07606] The mode / state of the beam-pointing is invalid
|
|
|
ERRORCODE: [07619] Insufficient signal at maximum gain
|