Thermal3 Command
(requires ENG access)
ibs sensor <gain> <offset>

Variables gain Specifies the sensor gain from 0 to 4095.
offset Specifies the sensor offset from 0 to 4095.

Description For the first version of the internal beam-balance sensor board, configure the internal beam-balance sensor gain and offset. The internal beam-balance sensor configuration will then be used when acquiring internal beam-balance sensor samples or if the optional token nocal is specified for the internal beam-balance sensor monitor commands.

Notes Thermal 1.0 / 1.7x equivalents:
  • The monitor command ibs sensor <gain> <offset> does not have an equivalent.

Thermal 2 equivalents:
  • The monitor command ibs sensor <gain> <offset> does not have an equivalent.

Related Documents COMMAND: ibs balance [nocal]
COMMAND: ibs profile [<increment>] [nocal]
COMMAND: ibs level <offset> [<width>] [nocal]
COMMAND: ibs sample
ERRORCODE: [07612] Failure configuring the internal beam-balance sensor
ERRORCODE: [07622] The board version does not support the functionality

Applies to: THERMAL3
Access: ENG
Modified: Wed Jul 16 04:28:34 2008
Updated: Wed Jul 16 04:52:22 2008
Module: IBS