Re-initialize the edge detect state including the logic to generate the interrupt for the host. If the edge detect is invalid, the edge detect state must be re-initialized before continuing the search for the edge of the media.
|
|
| Note that the "Standard" edge detect control mode requires that the edge detect start off-plate and the "Featureless" edge detect control mode requires that the edge detect start on-plate. Re-initializing the edge detect state will also verify the starting conditions for the edge detect.
|
Thermal 1.0 / 1.7x equivalents:
|
|
|
- The monitor command sys edge reset does not have an equivalent.
|
|
| Thermal 2 equivalents:
|
|
|
- The monitor command sys edge reset is equivalent to sys edge reset.
|
COMMAND: sys edge [standard|featureless|off]
|
|
|
PARAMETER: sys plotenable
|
|
|
ERRORCODE: [05611] The edge detect state is invalid ( on / off plate )
|
The monitor command sys edge reset corresponds to the API function CEH_EdgeReset( ) in the CEH API document.
|