Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Thermal 3 Errorcode: [05611] The edge detect state is invalid ( on / off plate )

Error details

Thermal3 Errorcode: [05611] The edge detect state is invalid ( on / off plate )
Thermal3 Errorcode
[05611] The edge detect state is invalid ( on / off plate )

Service Information The "Standard" edge detect control mode requires that the edge detect start off-plate and the "Featureless" edge detect control mode requires that the edge detect start on-plate. Before initiating the edge detect, the host will reset the edge detect state. This error indicates that the edge detect state is invalid for the edge detect control mode.

Operator Action Verify the loading of the plate and the plate size defined by the host.

Causes
  • The edge detect is being initiated in an invalid location.

Related Documents COMMAND: sys edge reset

Applies to: THERMAL3
Modified: Wed Jul 16 04:28:39 2008
Updated: Wed Jul 16 04:52:19 2008
Module: SYS

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.