Thermal3 Parameter
(requires ENG access)
hlt mask2

Description The health subsystem will monitor various metrics and abort a plot, prevent plotting, reset the exposure head, etc, as required by the metrics. This NVS parameter sets / clears the metric mask that will prevent specific metric points from being monitored.

While this parameter can be used to set / clear the metric mask for the metric points, it is recommended that the monitor command hlt mask (on|off) <index> be used to set / clear the metric mask for the metric points. The parameters are implemented for permanent storage only.

Type Integer

Default Value 0x00000000

Range 0x00000000 to 0xFFFFFFFF

Firmware Notes COMMAND: hlt mask [(on|off) <index>]
PARAMETER: hlt mask0
PARAMETER: hlt mask1
PARAMETER: hlt mask3
PARAMETER: hlt mask4

Applies to: THERMAL3
Access: ENG
Modified: Wed Jul 16 04:28:34 2008
Updated: Wed Jul 16 04:52:22 2008
Module: HLT