| Description | The health subsystem will monitor various metrics and abort a plot, prevent plotting, reset the exposure head, etc, as required by the metrics. This NVS parameter sets / clears the metric mask that will prevent specific metric points from being monitored. | |
| While this parameter can be used to set / clear the metric mask for the metric points, it is recommended that the monitor command hlt mask (on|off) <index> be used to set / clear the metric mask for the metric points. The parameters are implemented for permanent storage only. | ||
| Type | Integer | |
| Default Value | 0x00000000 | |
| Range | 0x00000000 to 0xFFFFFFFF | |
| Firmware Notes |
COMMAND: hlt mask [(on|off) <index>] | |
|
PARAMETER: hlt mask0 | ||
|
PARAMETER: hlt mask1 | ||
|
PARAMETER: hlt mask3 | ||
|
PARAMETER: hlt mask4 | ||