| Variables | copy index | The copy index from 0 to 3. |
| Description | The plot subsystem implements configureable test patterns for the test pattern generator. This NVS parameter configures the pattern number of the TPG pattern. | |
| While this NVS parameter can be used to configure the TPG pattern, it is recommended that the monitor commands plt pattern config <index> <pattern> <name> <row> <repeat> <column> and plt pattern init <index> <row> <nibbles> be used to configure the TPG pattern. | ||
| Type | Integer | |
| Default Value | 65535 | |
| Range | 0 to 65535 | |
| Related Documents |
COMMAND: plt pattern config <index> <pattern> <name> <row> <repeat> <column> | |
|
COMMAND: plt pattern init <index> <row> <nibbles> | ||
|
PARAMETER: plt <copy index> patternname | ||
|
PARAMETER: plt <copy index> rownumber | ||
|
PARAMETER: plt <copy index> rowrepeat | ||
|
PARAMETER: plt <copy index> columnnumber | ||
|
PARAMETER: plt <copy index> patterndata <data index> | ||