Thermal3 Parameter
(requires ENG access)
sys bipolarcal

Description Specifies whether the bipolar calibration is enabled or disabled.

If the bipolar calibration is disabled ( this NVS parameter is false ), the exposure head will attempt to execute the write laser and stroke calibration commands. This configuration is the default.

If the bipolar calibration is enabled ( this NVS parameter is true ), the exposure head will ignore the write laser and stroke calibration commands. Note that this configuration is intended only for debugging and / or development purposes.

Note that either the NVS parameter sys plotenable, the NVS parameter sys bipolarcal or the NVS parameter sys laserenable will disable the write laser and stroke calibration.

Type Boolean

Default Value False

Related Documents COMMAND: laser (on|off)
COMMAND: stroke cal
COMMAND: sys laser [on|standby|off|anneal]
COMMAND: sys stroke cal
PARAMETER: sys plotenable
PARAMETER: sys laserenable

Applies to: THERMAL3
Access: ENG
Modified: Wed Jul 16 04:28:39 2008
Updated: Wed Jul 16 04:52:22 2008
Module: SYS