Specifies whether the bipolar calibration is enabled or disabled.
|
|
| If the bipolar calibration is disabled ( this NVS parameter is false ), the exposure head will attempt to execute the write laser and stroke calibration commands. This configuration is the default.
|
|
| If the bipolar calibration is enabled ( this NVS parameter is true ), the exposure head will ignore the write laser and stroke calibration commands. Note that this configuration is intended only for debugging and / or development purposes.
|
|
| Note that either the NVS parameter sys plotenable, the NVS parameter sys bipolarcal or the NVS parameter sys laserenable will disable the write laser and stroke calibration.
|
Boolean
|
False
|
COMMAND: laser (on|off)
|
|
|
COMMAND: stroke cal
|
|
|
COMMAND: sys laser [on|standby|off|anneal]
|
|
|
COMMAND: sys stroke cal
|
|
|
PARAMETER: sys plotenable
|
|
|
PARAMETER: sys laserenable
|