| Description | Initiate a stroke calibration. | |
| While the monitor command stroke cal will perform a stroke calibration in blocking mode ( the monitor command will wait for completion ), the monitor commands sys stroke cal and sys stroke cal state will perform a stroke calibration in non-blocking mode ( the monitor commands will return immediately ). This allows multiple functions to be performed simultaneously. | ||
| For example, the user can use the monitor command sys stroke cal to initiate the stroke calibration. If successful, the exposure head will perform the stroke calibration while the user can continue with other processing ( for example, initiating a focus learn ). The user can use the monitor command sys stroke cal state to determine the status of the stroke calibration. | ||
| If the user attempts to access the write laser while the exposure head is performing the stroke calibration ( for example, to re-turn on the laser ), an error will indicate that a command is in progress. However, the user can use the monitor command sys plot abort to abort the stroke calibration. | ||
| Notes | Thermal 1.0 / 1.7x equivalents: | |
| ||
| Thermal 2 equivalents: | ||
| ||
| Related Documents |
COMMAND: laser (on|off) | |
|
COMMAND: stroke cal | ||
|
COMMAND: sys plot (init|start|pause|restart|stop|abort) | ||
|
COMMAND: sys laser [on|standby|off|anneal] | ||
|
COMMAND: sys stroke cal state | ||
|
PARAMETER: sys plotenable | ||
|
PARAMETER: sys bipolarcal | ||
|
PARAMETER: sys laserenable | ||
|
ERRORCODE: [05633] The stroke calibration is in progress | ||
|
ERRORCODE: [05636] Timeout waiting for the stroke calibration | ||
|
ERRORCODE: [05639] The stroke calibration has been aborted | ||
| Firmware Notes | The monitor command sys stroke cal corresponds to the API function CEH_StrokeCalInitiate( ) in the CEH API document. | |