Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Trendsetter News Firmware Release Summary 

 

If you have any questions relating to the information on this page, contact Mike Bogelund.

Version Status Part # / ECO Date Notes
1.17   19-3327?-?

/E706

May 17, 2002 Major features: Please see release notes.
1.16   19-3327A-C

/E706

Mar 2002 Major features:
  • Fix to reduce the occurrence of "trailing edge clamps not on actuator" error. The firmware now reads the TEC magnet sensor multiple times before reporting that the clamps are missing.
  • Delay in turning on and off the whisker jet.
  • For machines with toe-in pin configuration, plates larger than 750mm should now be centered in the bay (threshold used to be 800mm.
1.14   19-3327A-B

/E278

Aug 2001 Major features:
  • full support for plotting with 1200dpi head
  • support for B1 format
  • ability to ignore double edges during edge detect
  • support for debris removal monitoring
  • support for a processor interface
1.10  Build 4 Beta   May 2001
  • Ignores double edges if set temp b4 is set to 2.
  • Update the plot percent complete every 1s instead of 10s.
  • Fixed reporting so error while drum is stopping at end of plot will be reported properly.
1.0 Official Release 19-3327A-A

/D650

Dec 2000 Fixes several drum problems:
  • "timeout waiting for drum move" during unload
  • "position error greater than 1000 ticks" during unload
  • "drum is spinning" during unload
  • "Drum position counter overrun, Index not detected" during imaging
1.0  Build 24 Pre-release   Nov 2000 Properly supports new carriage and drum drives.

Some changes to increase throughput.

 


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.