| Version | Status | Part # / ECO | Date | Notes |
| 2.51a | 19-3049E-C
/E207 |
May 2001 | Uses Thermal head firmware version 1.74.
Upgrade to E-series Xilinx MPE board (10-3692) recommended. Use this version instead of 2.50 Bug fixes:
|
|
| 2.50a | 19-3049E-B
/D908 |
Dec 2000 | Uses Thermal head firmware version 1.62.
Bug fix to scaling problem introduced in 2.40a. Notes:
|
|
| 2.40a | 19-3049E-A
/D779 |
Sep 2000 | Uses Thermal head firmware version 1.56.
Bug fix for load cal command when using small plates. |
|
| 2.32a | 19-3049D-C
/D242 |
Nov 1999 | Uses Thermal head firmware version 1.38.
Subscan shift (gc sss) negative range increased from -10 mils to -150 mils (only used in 3244E). Note: It is not necessary to upgrade to this version from 2.31. The main purpose of this release is to provide a bug fix for 3244E Trendsetters |
|
| 2.31a | 19-3049D-B
/D106 |
Aug 1999 | Uses Thermal head firmware version 1.38
Trailing edge cylinder delay (aldly teul) default changed from 1 second
to 4 seconds. Note: It is not necessary to upgrade to this version from 2.30. The main purpose of this release is to provide support for 3244E Trendsetters |
|
| 2.30a | 19-3049D-A
/C947 |
May 1999 | Uses Thermal head firmware version 1.38 (release notes
indicate 1.36, no longer a valid version).
Chiller system enabled by default in NVS |
|
| 2.20a | 19-3049C-A
/C612 |
Nov 1998 | Uses Thermal head firmware version 1.30.
Supports media requiring carrier plates |
|
| 2.13a | 19-3049B-D
/C455 |
Aug 1998 | Uses Thermal head firmware version 1.23
Bug causing random focusing errors on plates requiring more than 255 swaths to complete imaging fixed. |
|
| 2.12a | 19-3049B–C
/C347 |
Jun 1998 | Uses Thermal head firmware version 1.23.
Set alpos calibration parameter changes |
|
| 2.11a | 19-3049B–B | Apr 1998 | Uses Thermal head firmware version 1.23.
External alarm implemented |
|
| 2.10a | 19-3049B–A | Feb 1998 | Uses Thermal head firmware version 1.23.
Support for staccato wide/narrow imaging |
|
| 2.09a | 19-3049A–F | Mar 1998 | Uses Thermal head firmware version 1.18.
SCSI 8-bit transfer mode bug fixed |
|
| 2.08a | 19-3049A–E | Feb 1998 | Uses Thermal head firmware version 1.18.
Fixed bug causing firmware crash on slow rips |
|
| 2.07a | (Appears on one service CD, no ECO)
Problems: Exit door act command lost 813 mm plate size not accepted (< 812 mm only) |
|||
| 2.06a | 19-3049A–D | Dec 1997 | Uses Thermal head firmware version 1.18.
Time engine command bug fixed |
|
| 2.05a | 19-3049A–C | Oct 1997 | Uses Thermal head firmware version 1.18 or 1.15.
Potential hang-up fixed |
|
| 2.04a | 19-3049A–B | Jun 1997 | Uses Thermal head firmware version 1.18 or 1.15.
LEC always released before drum move |
|
| 2.03a | May 1997 | Uses Thermal head firmware version 1.18 or 1.15.
Point release: Parameter updates allowed after plate loaded |
||
| 2.02a | Apr 1997 | Uses Thermal head firmware version 1.18 or 1.15.
Point release |
||
| 2.01a | Jan 1997 | Uses Thermal head firmware version 1.18 or 1.15.
Point release: Improved carriage acceleration (non-linear) |
||
| 2.00a | 19-3049A-A | Nov 1996 | Uses Thermal head firmware version 1.05 or 1.03.
First production release: |
|
| 1.60a | Jun 1996 | Uses Thermal head firmware version 1.18 or 1.15.
First beta release |