Version Status Part # / ECO Date Notes
2.51a   19-3049E-C

/E207

May 2001 Uses Thermal head firmware version 1.74.

Upgrade to E-series Xilinx MPE board (10-3692) recommended. Use this version instead of 2.50 

Bug fixes: 

  • Drum error reporting corrected
  • Drum initialization problem corrected
  • Drum speed series plot problem corrected
  • Load light functionality for diagnostic loads corrected
  • Resume and clear when not suspended no longer dump unexpected messages.
2.50a   19-3049E-B

/D908

Dec 2000 Uses Thermal head firmware version 1.62.

Bug fix to scaling problem introduced in 2.40a. 
Bug fix for checksum errors in servo_stat subsystem. 

Notes: 

  • Drum initialization errors occur when using this version with E-version Xilinx MPE boards (10-3692A) and a Creo Encoder (9000 line). A correction to this problem will be available shortly.
  • Drum errors in the range from 6025-6041 will have the incorrect error text associated with them. Use list error to determine the correct error.
2.40a   19-3049E-A

/D779

Sep 2000 Uses Thermal head firmware version 1.56.

Bug fix for load cal command when using small plates.
Version removed due to potential scaling problems.

2.32a   19-3049D-C

/D242

Nov 1999 Uses Thermal head firmware version 1.38.

Subscan shift (gc sss) negative range increased from -10 mils to -150 mils (only used in 3244E).

Note: It is not necessary to upgrade to this version from 2.31. The main purpose of this release is to provide a bug fix for 3244E Trendsetters

2.31a   19-3049D-B

/D106

Aug 1999 Uses Thermal head firmware version 1.38

Trailing edge cylinder delay (aldly teul) default changed from 1 second to 4 seconds. 
Mainscan shift (gc mss) default changed from 300 mils to 240 mils to support larger imageable areas for new presses.

Note: It is not necessary to upgrade to this version from 2.30. The main purpose of this release is to provide support for 3244E Trendsetters

2.30a   19-3049D-A

/C947 

May 1999 Uses Thermal head firmware version 1.38 (release notes indicate 1.36, no longer a valid version). 

Chiller system enabled by default in NVS 
Overwriting mode support 
Additional diagnostic plots (see release notes). 
Stroke cal updates done correctly for wide and narrow modes.

2.20a   19-3049C-A

/C612

Nov 1998 Uses Thermal head firmware version 1.30.

Supports media requiring carrier plates 
Special plot mode for ablative "Volcano" media 
Supports "Dylux" blueline proofing media Minimum mainscan size reduced 
Improved safety when door opened 
Supports large mainscan offsets  
Improved drum breaking safety Supports "Heidenhain" drum encoder 
Carriage maximum speed default value reduced 
Single-key macro ‘sat stat ldr’ reinstated 
Drum calibration procedure corrected 
Abort now detected while waiting for button press

2.13a   19-3049B-D

/C455 

Aug 1998 Uses Thermal head firmware version 1.23

Bug causing random focusing errors on plates requiring more than 255 swaths to complete imaging fixed.

2.12a   19-3049B–C

/C347

Jun 1998 Uses Thermal head firmware version 1.23.

Set alpos calibration parameter changes 
Set al calibration parameter changes 
Set aldly calibration parameter changes 
Set altim calibration parameter changes 
Maximum image size increased 
Orthog slope larger than max error now a warning mload and munload commands replaced  
Resume and clear commands added 
Unsafe act commands removed 
Timeout on exit door when plate sensor absent 
Device and model query from ws supported 
Firmware version query from ws supported 
Single key macro commands changed

2.11a   19-3049B–B Apr 1998 Uses Thermal head firmware version 1.23.

External alarm implemented 
Maximum mscan plate size now spaced at 33"  
Plate flyoff recovery bug fixed Warning if FDPE and PHI boards both present 
Trailing edge ticks bug fixed 
First swath shift bug fixed 
Phantom scanline fixed 
Other minor bugs fixed (see release notes)

2.10a   19-3049B–A Feb 1998 Uses Thermal head firmware version 1.23.

Support for staccato wide/narrow imaging 

2.09a   19-3049A–F  Mar 1998 Uses Thermal head firmware version 1.18.

SCSI 8-bit transfer mode bug fixed

2.08a   19-3049A–E Feb 1998 Uses Thermal head firmware version 1.18.

Fixed bug causing firmware crash on slow rips 
Addition to set command list 
Changes to nvs backup and restore procedure 
Support for 3230 trendsetters 
Support for FDPE boards

2.07a       (Appears on one service CD, no ECO) 

Problems: Exit door act command lost 813 mm plate size not accepted (< 812 mm only)

2.06a   19-3049A–D Dec 1997 Uses Thermal head firmware version 1.18.

Time engine command bug fixed 
Drum safety improved 
Beam balance done after reset head 
SCSI inquiry response now has correct length 
Plate now door closes after image aborted 
Engine electronics board detection & warnings 
Support for Xilinx ‘E’ series chips 
Drum amplifier calibration 
New thermal module 
Improved edge detection

2.05a   19-3049A–C Oct 1997 Uses Thermal head firmware version 1.18 or 1.15.

Potential hang-up fixed 
Improved edge detection  
Plotting complete message now sent to ws 
Load ramp tilt clearance nvs parameter added 
Pushbutton no longer latched

2.04a   19-3049A–B Jun 1997 Uses Thermal head firmware version 1.18 or 1.15.

LEC always released before drum move 
Drum can’t move if any actuator down 
Mask table changes (unused items deleted) 
New carriage system cable detects added  
Operator interface board cable detects fixed 
Flush command no longer hangs if init fails 
MPE won’t reset if ALE not installed 
Indefinite wait for image DPI (mode) from ws 
Searching for edge in progress message added  
Beam balance in progress message added 
Image task verbose messages added 
ALE status command improved 
Beeper may now be disabled 
Support added for short load ramp 
Plate measurement uses single sensor  
Support added for multiple images on one plate

2.03a     May 1997 Uses Thermal head firmware version 1.18 or 1.15.

Point release: Parameter updates allowed after plate loaded

2.02a     Apr 1997 Uses Thermal head firmware version 1.18 or 1.15.

Point release

2.01a     Jan 1997 Uses Thermal head firmware version 1.18 or 1.15.

Point release: Improved carriage acceleration (non-linear)
New test patterns added
Set sys ism to non-zero no longer necessary
Blank plate and other SCSI problems fixed
Statistical timer accuracy fixed

2.00a   19-3049A-A Nov 1996 Uses Thermal head firmware version 1.05 or 1.03.

First production release: 

Improved error handling Improved error checking of ws mage commands
Hanging during edge detection fixed
Hanging during SCSI initialization fixed
Load time-out removed
Unload time-out removed
Parameters update commmand for ws supported
Exit flap stays closed until drum is ready for plate
Plate center motor support removed
Flush command from ws supported
Small plate size support added 
Minimum plate sizes changed
Support added for film unloading
Plate is measured during load
Plate always unloaded on error
Nvs sys load 0 command added for testing
Verbose messaging by task
Irrelevent mask table entries removed
New command name to disable plate sensors

1.60a     Jun 1996 Uses Thermal head firmware version 1.18 or 1.15.

First beta release

 