Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
If you have any questions relating to the information on this page, contact Mike Bogelund.
| Version | Status | Part # / ECO | Date | Notes |
| 2.53b | Controlled Release 1.2 | 19-3143E-E
/CA00778 |
May 1, 2003 | Uses Thermal head firmware version 1.83 Warning: Do NOT issue the NVS UPGRADE HEAD 1.62 command if this has been done when the device was upgraded to 2.51b or 2.52b. Doing so may result in corruption of HDM parameters. See Release Notes for details. |
| 2.52b | 19-3143E-D
/E864 |
Jun 2002 | Uses Thermal head firmware version 1.74
Warning: Do NOT issue the NVS UPGRADE HEAD 1.62 command if this has been done when the device was upgraded to 2.51b. Doing so may result in corruption of HDM parameters. Support for new models:
Bug fixes:
See Release Notes for details. |
|
| 2.51b | 19-3143E-C
/E207 |
May 2001 | Uses Thermal head firmware version 1.74.
Upgrade to E-series Xilinx MPE board (10-3692) recommended. Bug fixes:
|
|
| 2.50b | 19-3143E-B
/D908 |
Dec 2000 | Uses Thermal head firmware version 1.62.
Support for S, F, and V model machines. Bug fix: NVS checksum warning in servo_stat problem fixed. Notes: Drum initialization problems occur on machines using the
Creo Encoder (9000 line) when using this version. A patch will be
available shortly. |
|
| 2.40b | 19-3143E-A
/D779 |
Sep 2000 | Uses Thermal head firmware version 1.56.
This version has been removed, please use 2.51b. Note: There may be NVS Checksum error warnings regarding the servo_stat block on startup with some heads which can be safely ignored. |
|
| 2.32b | 19-3143D-C
/D242 |
Nov 1999 | Uses Thermal head firmware version 1.38
Bug fixes for 3244E Trendsetters: Subscan shift (gc sss) negative range increased from -10 mils to -150 mils (only used in 3244E). Support for larger than 44 inch (subscan) plates. Note: It is not necessary to upgrade to this version from 2.30b. The main purpose of this release is to fix support for 3244E Trendsetters (which must upgrade to this version) |
|
| 2.31b | 19-3143D-B
/D106 |
Aug 1999 | Uses Thermal head firmware version 1.38.
Support for 3244E Trendsetters Trailing edge cylinder delay (aldly teul)
changed from default of 1 second to 4 seconds |
|
| 2.30b | 19-3143D-A
/C947 |
May 1999 | Uses Thermal head firmware version 1.38 (Release notes
indicate 1.36, no longer a valid version).
Chiller system enabled by default in NVS |
|
| 2.20b | 19-3143C-A
/C612 |
Nov 1998 | Uses Thermal head firmware version 1.30.
Supports liquid cooling system for thermal head |
|
| 2.13b | 19-3143B-D
/C455 |
Aug 1998 | Uses Thermal head firmware version 1.23.
Bug causing random focussing errors on plates requiring more than 255 swaths to complete imaging fixed. |
|
| 2.12b | 19-3143B–C
/C347 |
Jun 1998 | Uses Thermal head firmware version 1.23 Set alpos calibration parameter changes Set al calibration parameter changes Set al configuration parameter changes Set aldly calibration parameter changes Set altim calibration parameter changes Maximum image size increased Orthog slope larger than max error now a warning mload and munload commands replaced Resume and clear commands added Unsafe act commands removed Timeout on exit door when plate sensor absent Device and model query from ws supported Firmware version query from ws supported Single key macro commands changed | |
| 2.11b | 19-3143B–B | Apr 1998 | Uses Thermal head firmware version 1.23.
External alarm implemented |
|
| 2.10b | 19-3143B–A | Feb 1998 | Uses Thermal head firmware version 1.23.
Support for stacatto wide/narrow imaging. |
|
| 2.09b | 19-3143A–D | Mar 1998 | Uses Thermal head firmware version 1.18.
SCSI 8-bit transfer mode bug fixed. |
|
| 2.08b | 19-3143A–C | Feb 1998 | Uses Thermal head firmware version 1.18.
Fixed bug causing firmware crash on slow rip’s |
|
| 2.07b | (Appears on one service CD, no ECO) Problems: Exit door act command lost 813 mm plate size not accepted (< 812 mm only) |
|||
| 2.06b | 19-3143A–B | Dec 1997 | Uses Thermal head firmware version 1.18.
Time engine command bug fixed Engine electronics board detection & warnings |
|
| 2.05b | 19-3143A–A | Oct 1997 | Uses Thermal head firmware version 1.18 or 1.15
Potential hang-up fixed |