Description: |
Plots a surface depth series, where: The <pattern> parameter is an integer specifying which built-in test pattern to use. Use the list pattern command to display the available patterns. The <start> parameter specifies the starting value in microns, which can be negative. The range is the same as for the media NVS surface depth parameter. The <increment> parameter specifies the step size, also in microns. For example, "plot 80 sd -10 2" will plot pattern #80 several times over the width of the media on the drum, starting with the surface depth set to -10 microns and incrementing it 2 microns with each series step. The current media NVS parameter "sd" is ignored during a sd series. The number of steps and the width of each stripe are set by the hdp NVS parameters "fmsl" and "fmsw" respectively. |
Applies To: |
|
Syntax: |
plot <pattern> [<length>] sd <start> <increment> |
Notes: |
See Also: |