NVS Parameter: hdp fmsl


Long Name:

f_m_series_length

Applies to:

  • Green
  • Thermal

  • Description:

    Total number of strips, or steps, to image when performing a test plot series such as a focus, or delay series. The length of each strip is set with the hdp fmsw parameter.

    For Thermal, fmsl is used with focus, bmslope, bmcurve, wpower, drum speed, and surface depth series.

    For Green, fmsl is used with focus, delay and magnification series.


    Type:

    integer

    Default:

    • 4 (Green)
    • 20 (Thermal)

    Range:

    • 0 to 20 [steps]

    Notes:

    This parameter is ignored when the series plot width is specified in the plot series command, in which case the number of strips is calculated to fit in the specified width.


    Partition:

    cal

    See Also:

  • NVS: hdp fmsw
  • NVS: hdm bmslope
  • NVS: hdm bmcurve
  • NVS: hdm wpower
  • NVS: hdm ds
  • NVS: media sd
  • Command: plot
  • Command: plot focus
  • Command: plot bmslope
  • Command: plot bmcurve
  • Command: plot wpower
  • Command: plot ds
  • Command: plot sd

  • Go to CTP Firmware NVS Parameter Index Page