NVS Parameter: hdp fmsw


Long Name:

f_m_series_width

Applies to:

  • Green
  • Thermal

  • Description:

    Green - The length of each strip when performing a focus, delay, or magnification series.

    Thermal - Specifies the width of each stripe in a focus, bmcurve, bmslope, wpower , drum speed, or a surface depth series test plot.

    The strip width should be chosen to match the repeat period of the test pattern. The green default width is chosen to match test pattern 8. Note that "continuous" patterns like the percent screens (30, 50, 80, etc) will work well with any strip width because they do not have a repeat period.


    Type:

    real

    Default:

    • 4.5 (Green)
    • 1.0 (Thermal)

    Range:

    • 0.01 to 20 [inches]

    Notes:


    Partition:

    cal

    See Also:

  • NVS: hdp fmsl
  • NVS: hdm bmslope
  • NVS: hdm bmcurve
  • NVS: hdm wpower
  • NVS: hdm ds
  • NVS: media sd
  • Command: plot
  • Command: plot focus
  • Command: plot bmslope
  • Command: plot bmcurve
  • Command: plot wpower
  • Command: plot ds
  • Command: plot sd

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page