Error Number: 3039


Error Message:

WSCOMM: Plate lost during pick, check inside cassette drawer <number>


Applies to:

  • Platesetter_VLF
  • Platesetter_3244

Service Information:

Platesetter_3244

Platesetter 3244 firmware 2.25 will report the measured picker vacuum on the diagnostic monitor. This should be compared to the 'sat pvt' threshold value and 'cal pvac' should be performed. Some problems have been experienced with the ADC on the ALE board at higher temperatures (35C)

If the plate was not really dropped but the threshold or sensor was meerly wrong, then the picker will attempt to return the plate to the box.

Platesetter_VLF:


Operator Action:

Resume


Cause:

  • Platesetter_3244: picker is read and compared to the picker_vacuum_threshold, if it is less than pvt when a plate is expected to be on the picker then this error is reported. Platesetter_VLF:

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page