Error Number: 3048


Error Message:

WSCOMM: Image too wide for plate


Applies to:

  • All

Service Information:

The workstation has sent an image that, by the recorder's calculation, is wider than the plate, i.e. along the drum axis.

There is a bug in early HRX firmware that can cause this error. The workaround is to change the "set sys ism" parameter to 3. No harm can be caused by setting this parameter, even if it doesn't fix the error.


Operator Action:

Reload the bay, double checking plate size. This error may also be caused by a problem with the RIP or the Postscript file. Record the plate colour(s) that have this error and call Creo Service if the plate size is ok.


Cause:

  • Mismatch between the plate widths entered in the recorder and the workstation
  • Imposition or RIP error

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page