Error Number: 7006


Error Message:

CARRIAGE: timed out while waiting for LCA position


Applies to:

  • All

Service Information:

This error indicates either a failure of the carriage Xilinx controller on the ALE or a firmware bug. The responsible firmware programmer should be contacted with details of the error. There may be a known firmware or hardware bug that causes this error. Otherwise, the ALE should be replaced.

This error has been reported if the default mode (generally mode 1) is not configured properly on startup. Check the "set mode 1 dpi" setting. If it is 0, set it to a reasonable value, save it, then reset the machine.


Operator Action:

Record error message and contact Creo service


Cause:

  • Possible failure of the ALE
  • Default mode is invalid on startup
  • Currently unknown firmware or hardware bug

See Also:


Go to CTP Firmware Error Index Page