Error Message: |
CARRIAGE: Carriage control board error: over temperature |
Applies to: |
|
Service Information: |
The carriage driver has reported a fault. Control signals: status0 is low (active) and status1 is high (inactive). Check the cables running to and from the carriage driver board. Also check the voltage levels on the board. If an over temperature fault has occured, the OT and FAULT LED will be asserted on the carriage drive board. This error may cause a momentary fault to be displayed at the diagnostic terminal. To verify if this has occured, check that the OT LED is asserted before reseting or intializing the carriage. This error is only applicable if the new carriage driver is installed. In that case, the "sys hpd (high_pwr_drives)" will be set to 1. |
Operator Action: |
Click on CANCEL IMAGE. If the machine does not recover, turn the power to the output machine off and on again. Please contact Creo Service to report this error. |
Cause:
|
See Also: |
|
Go to CTP Firmware Error Index Page
Go to CTP Firmware Error Search Page