Error Number: 10060


Error Message:

HARDWARE: External Debris Blower Filters Not Present


Applies to:

  • All

Service Information:

The debris cabinet is reporting that the filters are not present. Check the filter itself, the sensor inside the cabinet, and the cable running to the device.

If everything looks fine, the error can be masked off temporarily in later versions of firmware. Check the mask table for "DBlower Filter Fault".


Operator Action:

The device cannot detect the debris filter inside the debris cabinet. Open the cover of the cabinet and check to make sure the filter is sitting solidly inside the cabinet. Check the cable running from the debris cabinet to the device. If it is loose, plug it in securely and try again. If everything looks fine and the error comes up again, contact the CreoScitex Response Centre.


Cause:

  • Filter has been removed from debris cabinet.
  • Faulty cable from debris cabinet to device.
  • Faulty sensor inside debris cabinet.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:30 2002 PST