Error Number: 10065


Error Message:

HARDWARE: DBlower Filter Fault.


Applies to:

  • All

Service Information:

The debris cabinet is reporting that the filters are not present. Check the filter itself, the sensor inside the cabinet, and the cable running to the device.

If everything looks fine, the error can be masked off temporarily in later versions of firmware.


Operator Action:

This error should not be reported to the workstation. If it does, contact the CreoScitex Response Centre.


Cause:

  • Filter has been removed from debris cabinet.
  • Faulty cable from debris cabinet to device.
  • Faulty sensor inside debris cabinet.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page