Error Number: 15071


Error Message:

ALE: remove plate from drum


Applies to:

  • All

Service Information:

The drum vacuum indicates that something is on the drum OR the "state plate_loc d status" indicates that the drum is not empty. If the drum is actually empty, in the first case, check for whether the drum vacuum threshold is setup correctly (Spectrum only) in "proof n dvct" where n is the proof type number. If "dvct" check out ok, then check for obstructed vacuum holes on the drum.


Operator Action:

Open the machine's front panel and remove the plate which is on the drum. Select 'Plate Removed' to continue.


Cause:

  • Invalid drum vacuum carreir threshold setting (Spectrum only) Unknown reason caused machine to lost track of the status of the drum (usually due to the inproper use of "set state plate_loc d" command).

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:36 2002 PST