Error Number: 15076


Error Message:

ALE: trailing edge clamps not on actuator


Applies to:

  • All

Service Information:

If all the clamps are in place, check for faulty magnet sensor by using "tec" command. If it is faulty, use "set al ms 0" to bypass the sensor and get the customer going. Arrange for field service.


Operator Action:

Check if all the clamps are on the actuator. Place any missing clamp onto the actuator and select resume.


Cause:

  • Missing clamp on the TEC actuator
  • Faulty TEC magnet sensor

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:36 2002 PST